|
|
Registro Completo |
Biblioteca(s): |
Embrapa Caprinos e Ovinos. |
Data corrente: |
06/04/2006 |
Data da última atualização: |
04/04/2019 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
PINHEIRO, R. R.; GOUVEIA, A. M. G.; ALVES, F. S. F.; ANDRIOLI, A. |
Afiliação: |
RAYMUNDO RIZALDO PINHEIRO, CNPC; Aurora Maria Guimarães Gouveia, UFMG, Belo Horizonte, MG.; FRANCISCO SELMO FERNANDES ALVES, CNPC; ALICE ANDRIOLI, CNPC. |
Título: |
Medidas carpo-metacarpianas como índice articular clínico em caprinos. |
Ano de publicação: |
2005 |
Fonte/Imprenta: |
Revista Brasileira de Medicina Veterinária, Rio de Janeiro, v. 27, n. 4, p. 170-173, out./dez. 2005. |
Idioma: |
Português |
Palavras-Chave: |
Brasil; Ceará; Índice; Medida. |
Thesagro: |
Articulação; Artrite; Caprino. |
Categoria do assunto: |
-- |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/85853/1/API-Medidas-carpo-metacarpianas.pdf
|
Marc: |
LEADER 00648naa a2200229 a 4500 001 1531876 005 2019-04-04 008 2005 bl uuuu u00u1 u #d 100 1 $aPINHEIRO, R. R. 245 $aMedidas carpo-metacarpianas como índice articular clínico em caprinos. 260 $c2005 650 $aArticulação 650 $aArtrite 650 $aCaprino 653 $aBrasil 653 $aCeará 653 $aÍndice 653 $aMedida 700 1 $aGOUVEIA, A. M. G. 700 1 $aALVES, F. S. F. 700 1 $aANDRIOLI, A. 773 $tRevista Brasileira de Medicina Veterinária, Rio de Janeiro$gv. 27, n. 4, p. 170-173, out./dez. 2005.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Caprinos e Ovinos (CNPC) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registro Completo
Biblioteca(s): |
Embrapa Caprinos e Ovinos. |
Data corrente: |
26/05/2010 |
Data da última atualização: |
23/09/2019 |
Tipo da produção científica: |
Resumo em Anais de Congresso |
Autoria: |
BRANDÃO, F. Z.; ARASHIRO, E. K. N.; HENRY, M.; FIGUEIRA, L. M.; SOUZA, J. M. C.; VIANA, J. H. M.; FONSECA, J. F. da. |
Afiliação: |
Universidade Federal Fluminense, Niteroi, RJ; Universidade Federal de Minas Gerais (UGMG), Belo Horizonte, MG; UFMG; Universidade Federal Fluminense; Universidade Federal de Viçosa (UFV), Viçosa, MG; JOAO HENRIQUE MOREIRA VIANA, CNPGL; JEFERSON FERREIRA DA FONSECA, CNPC. |
Título: |
Evaluation of superovulatory response in Santa Inês ewes by ultrasonography and laparoscopy. |
Ano de publicação: |
2010 |
Fonte/Imprenta: |
Reproduction, Fertility and Development, v. 22, n. 1, p. 242, 2010. |
DOI: |
10.1071/RDv22n1Ab167 |
Idioma: |
Inglês |
Notas: |
Edição dos Proceedings of the Annual Conference of the International Embryo Transfer Society, Córdoba, Argentina, 9?12 January 2010. |
Conteúdo: |
The development and use of non-invasive techniques would reduce risks of surgery sequels on the same animal and use of the donor could be optimized. The aim of this study was to evaluate the accuracy of ultrasonography performed prior to embryo collection to estimate superovulation response in sheep. Fifteen pluriparous Santa Inês sheep, 2 to 5 year old, with an average body weight of 46.79 ± 6.00 kg and body condition score of 2.96 ± 0.32 (1 to 5 scale) were allocated into 3 groups (GI, GII, GIII) in a cross-over design. In GI, intravaginal sponges (60 mg of medroxyprogesterone acetate; Progespon®, Schering Plough Animal Health, São Paulo, Brazil) were inserted (Day 0) and maintained for 14 days, and the superovulatory (SOV) protocol started on Day 12. In GII and GIII, intravaginal sponges were inserted (Day 0) and maintained for 6 days. On Day 5, the animals were treated with 300 IU of eCG (Novormon 5000®, Schering Plough Animal Health) and 5 mg of dinoprost (Lutalyse® Pfizer Animal Health, São Paulo, Brazil) i.m. Animals in GIII received 0.025 mg of gonadorelin acetate (Gestran-Plus®, Tecnopec, São Paulo, Brazil) i.m. 12 h after sponge withdrawal. In GII and GIII, the SOV protocol started 48 h after sponge removal and a new sponge was inserted immediately after its removal. The SOV protocol in all groups consisted of 200 mg of pFSH (Folltropin-V®, Tecnopec) administered in 6 decreasing doses given every 12 h (50/50, 30/30, and 20/20 mg). At the time of the fifth dose of pFSH, 5 mg of dinoprost was administered i.m. and the sponges were removed. Animals were bred by a sexually mature ram twice a day until the end of estrus. Prior to embryo collection, an ultrasonographic evaluation (5 MHz, Aloka SSD-500, Tokyo, Japan) was performed to determine the number of CL present on both ovaries. The number of CL was further evaluated by laparoscopy, when it was possible to detect poor responders or even non-ovulating animals. Statistical analysis was performed using all tests at the 95% confidence interval by SAEG program. Results are presented as mean ± SE. The number of CL was not different among all groups. The total number (GI, GII, and GIII) of CL determined by ultrasonography (9.09 ± 5.01) was not different (P > 0.05) from that observed by laparoscopy (8.87 ± 5.25). A significant correlation (r = 0.56, P < 0.0005) between evaluation performed by ultrasonography and laparoscopy was observed. These results suggest that ultrasonography can be used to determine the response to the superovulatory protocol. As embryo collection in sheep is performed mainly by surgical techniques, the implementation of non-invasive techniques such as ultrasonography could avoid unnecessary surgeries on animals that did not respond to the SOV protocol, therefore preventing early culling of embryo donors. Top Print this pagePrint Email this page View Issue Contents Abstract Export Citation Tools Print Bookmark Email this page Early Alert Subscribe to our Early Alerts for the latest journal issue contents. MenosThe development and use of non-invasive techniques would reduce risks of surgery sequels on the same animal and use of the donor could be optimized. The aim of this study was to evaluate the accuracy of ultrasonography performed prior to embryo collection to estimate superovulation response in sheep. Fifteen pluriparous Santa Inês sheep, 2 to 5 year old, with an average body weight of 46.79 ± 6.00 kg and body condition score of 2.96 ± 0.32 (1 to 5 scale) were allocated into 3 groups (GI, GII, GIII) in a cross-over design. In GI, intravaginal sponges (60 mg of medroxyprogesterone acetate; Progespon®, Schering Plough Animal Health, São Paulo, Brazil) were inserted (Day 0) and maintained for 14 days, and the superovulatory (SOV) protocol started on Day 12. In GII and GIII, intravaginal sponges were inserted (Day 0) and maintained for 6 days. On Day 5, the animals were treated with 300 IU of eCG (Novormon 5000®, Schering Plough Animal Health) and 5 mg of dinoprost (Lutalyse® Pfizer Animal Health, São Paulo, Brazil) i.m. Animals in GIII received 0.025 mg of gonadorelin acetate (Gestran-Plus®, Tecnopec, São Paulo, Brazil) i.m. 12 h after sponge withdrawal. In GII and GIII, the SOV protocol started 48 h after sponge removal and a new sponge was inserted immediately after its removal. The SOV protocol in all groups consisted of 200 mg of pFSH (Folltropin-V®, Tecnopec) administered in 6 decreasing doses given every 12 h (50/50, 30/30, and 20/20 mg). At the time of the fifth dose of p... Mostrar Tudo |
Palavras-Chave: |
Raça Santa Inês; Resposta ovariana; Ultra-Som. |
Thesagro: |
Ovino; Reprodução animal; Superovulação; Transferência de embrião. |
Thesaurus NAL: |
Animal reproduction; Sheep; Superovulation. |
Categoria do assunto: |
L Ciência Animal e Produtos de Origem Animal |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/61354/1/rac-EVALUATION-OF-SUPEROVULATORY.pdf
|
Marc: |
LEADER 04138nam a2200325 a 4500 001 1853920 005 2019-09-23 008 2010 bl uuuu u00u1 u #d 024 7 $a10.1071/RDv22n1Ab167$2DOI 100 1 $aBRANDÃO, F. Z. 245 $aEvaluation of superovulatory response in Santa Inês ewes by ultrasonography and laparoscopy.$h[electronic resource] 260 $aReproduction, Fertility and Development, v. 22, n. 1, p. 242$c2010 500 $aEdição dos Proceedings of the Annual Conference of the International Embryo Transfer Society, Córdoba, Argentina, 9?12 January 2010. 520 $aThe development and use of non-invasive techniques would reduce risks of surgery sequels on the same animal and use of the donor could be optimized. The aim of this study was to evaluate the accuracy of ultrasonography performed prior to embryo collection to estimate superovulation response in sheep. Fifteen pluriparous Santa Inês sheep, 2 to 5 year old, with an average body weight of 46.79 ± 6.00 kg and body condition score of 2.96 ± 0.32 (1 to 5 scale) were allocated into 3 groups (GI, GII, GIII) in a cross-over design. In GI, intravaginal sponges (60 mg of medroxyprogesterone acetate; Progespon®, Schering Plough Animal Health, São Paulo, Brazil) were inserted (Day 0) and maintained for 14 days, and the superovulatory (SOV) protocol started on Day 12. In GII and GIII, intravaginal sponges were inserted (Day 0) and maintained for 6 days. On Day 5, the animals were treated with 300 IU of eCG (Novormon 5000®, Schering Plough Animal Health) and 5 mg of dinoprost (Lutalyse® Pfizer Animal Health, São Paulo, Brazil) i.m. Animals in GIII received 0.025 mg of gonadorelin acetate (Gestran-Plus®, Tecnopec, São Paulo, Brazil) i.m. 12 h after sponge withdrawal. In GII and GIII, the SOV protocol started 48 h after sponge removal and a new sponge was inserted immediately after its removal. The SOV protocol in all groups consisted of 200 mg of pFSH (Folltropin-V®, Tecnopec) administered in 6 decreasing doses given every 12 h (50/50, 30/30, and 20/20 mg). At the time of the fifth dose of pFSH, 5 mg of dinoprost was administered i.m. and the sponges were removed. Animals were bred by a sexually mature ram twice a day until the end of estrus. Prior to embryo collection, an ultrasonographic evaluation (5 MHz, Aloka SSD-500, Tokyo, Japan) was performed to determine the number of CL present on both ovaries. The number of CL was further evaluated by laparoscopy, when it was possible to detect poor responders or even non-ovulating animals. Statistical analysis was performed using all tests at the 95% confidence interval by SAEG program. Results are presented as mean ± SE. The number of CL was not different among all groups. The total number (GI, GII, and GIII) of CL determined by ultrasonography (9.09 ± 5.01) was not different (P > 0.05) from that observed by laparoscopy (8.87 ± 5.25). A significant correlation (r = 0.56, P < 0.0005) between evaluation performed by ultrasonography and laparoscopy was observed. These results suggest that ultrasonography can be used to determine the response to the superovulatory protocol. As embryo collection in sheep is performed mainly by surgical techniques, the implementation of non-invasive techniques such as ultrasonography could avoid unnecessary surgeries on animals that did not respond to the SOV protocol, therefore preventing early culling of embryo donors. Top Print this pagePrint Email this page View Issue Contents Abstract Export Citation Tools Print Bookmark Email this page Early Alert Subscribe to our Early Alerts for the latest journal issue contents. 650 $aAnimal reproduction 650 $aSheep 650 $aSuperovulation 650 $aOvino 650 $aReprodução animal 650 $aSuperovulação 650 $aTransferência de embrião 653 $aRaça Santa Inês 653 $aResposta ovariana 653 $aUltra-Som 700 1 $aARASHIRO, E. K. N. 700 1 $aHENRY, M. 700 1 $aFIGUEIRA, L. M. 700 1 $aSOUZA, J. M. C. 700 1 $aVIANA, J. H. M. 700 1 $aFONSECA, J. F. da
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Caprinos e Ovinos (CNPC) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Expressão de busca inválida. Verifique!!! |
|
|